Sign In | Join Free | My burrillandco.com
Home > Industrial Servo Motor >

point Isolated Form A, 16 points IC200MDL940 GE VersaMax Discrete Output Module, Relay 2 .0 A per

Shenzhen Wisdomlong Technology CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap point Isolated Form A, 16 points IC200MDL940 GE VersaMax Discrete Output Module, Relay 2 .0 A per from wholesalers
     
    Buy cheap point Isolated Form A, 16 points IC200MDL940 GE VersaMax Discrete Output Module, Relay 2 .0 A per from wholesalers
    • Buy cheap point Isolated Form A, 16 points IC200MDL940 GE VersaMax Discrete Output Module, Relay 2 .0 A per from wholesalers
    • Buy cheap point Isolated Form A, 16 points IC200MDL940 GE VersaMax Discrete Output Module, Relay 2 .0 A per from wholesalers

    point Isolated Form A, 16 points IC200MDL940 GE VersaMax Discrete Output Module, Relay 2 .0 A per

    Ask Lasest Price
    Brand Name : GE
    Model Number : IC200MDL940
    Price : negotiable
    Payment Terms : T/T
    Supply Ability : 20
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    point Isolated Form A, 16 points IC200MDL940 GE VersaMax Discrete Output Module, Relay 2 .0 A per

    point Isolated Form A, 16 points IC200MDL940 GE VersaMax Discrete Output Module, Relay 2 .0 A per


    IC200MDL750IC200MDL930IC200MDL940
    Product NameVersaMax Discrete Output Module,
    24 VDC Positive Logic, 0 .5A per point,
    32 points
    VersaMax Discrete Output Module,
    Relay 2 .0 A per point Isolated
    Form A, 8 points
    VersaMax Discrete Output Module,
    Relay 2 .0 A per point Isolated
    Form A, 16 points
    Lifecycle StatusActiveActiveActive
    Output Voltage10 .2-30 VDC, 12/24 VDC nominal0-125 VDC, 5/24/125 VDC nominal;
    0-265 VAC (47-63 Hz),
    120/240 VAC nominal
    0-125 VDC, 5/24/125 VDC nominal;
    0-265 VAC (47-63 Hz),
    120/240 VAC nominal
    Number of Points32816
    Channel to Channel IsolationNoYesYes
    Load Current per Point0 .5 A per point2 .0 A for 5-265 VAC, 2 .0 A for 5-30 VDC,
    0 .2 A for 31-125 VDC
    2 .0 A for 5-265 VAC, 2 .0 A for 5-30 VDC,
    0 .2 A for 31-125 VDC
    Input and Output Response
    Time- On/Off (ms)
    0 .2/1 .010 .0/10 .010 .0/10 .0
    ProtectionNo internal fusesNo internal fuses or snubbersNo internal fuses or snubbers
    Points per Common2 groups of 16Isolated pointsIsolated points
    External Power Supply10 .2-30 VDC, 12/24 VDC nominal0-125 VDC, 5/24/125 VDC nominal; 0-265
    VAC (47-63 Hz), 120/240 VAC nominal
    0-125 VDC, 5/24/125 VDC nominal; 0-265
    VAC (47-63 Hz), 120/240 VAC nominal
    Load Current0 .5 A at 30 VDC maximum (resistive); 2 .0 A
    inrush maximum for 100 ms
    10 mA per point minimum; 2 .0 A for 5-265
    VAC maximum (resistive); 2 .0 A for 5-30 VDC
    maximum (resistive); 0 .2 A for 31-125 VDC
    maximum (resistive)
    10 mA per point minimum; 2 .0 A for 5-265
    VAC maximum (resistive); 2 .0 A for 5-30 VDC
    maximum (resistive); 0 .2 A for 31-125 VDC
    maximum (resistive)
    5V Backplane Current
    Consumption (mA)
    90 maximum245 maximum490 maximum
    LED IndicatorsOne LED per point shows individual
    point ON/OFF state (logic side) .
    FLD PWR LED indicates field power is
    present . OK LED indicates backplane
    power is present .
    One LED per point shows individual
    point ON/OFF state (logic side) .
    FLD PWR LED indicates field power is
    present . OK LED indicates backplane
    power is present .
    One LED per point shows individual
    point ON/OFF state (logic side) .
    FLD PWR LED indicates field power is
    present . OK LED indicates backplane
    power is present .
    Dimensions (W x H x D)110 mm (4 .3 in) x 66 .8 mm (2 .63 in) x
    50 mm (1 .956 in), not including the
    height of the carrier or the
    mating connectors
    110 mm (4 .3 in) x 66 .8 mm (2 .63 in) x
    50 mm (1 .956 in), not including the
    height of the carrier or the
    mating connectors
    110 mm (4 .3 in) x 66 .8 mm (2 .63 in) x
    50 mm (1 .956 in), not including the
    height of the carrier or the
    mating connectors

    Discrete Output Modules


    Discrete output modules send control signals to devices such as contactors, indicator lamps, and
    interposing relays that can also have two states . Modules require a carrier base (IC200CHSxxx) .


    Our Brands:
    【Honeywell】 Module DCS/PLC/Transmitter
    【Emerson/Delta V】 Module/ CT Motor & Drives
    【ABB】 I/O Module
    【AB】 Module&Touch Screen
    【Rosemount】 Transmitter
    【Yokogawa】 Transmitter
    【Yaskawa】 Servo Drive&Servo Motor
    【GE/Fanuc】 IC69 Series PLC
    【Mitsubishi】 Servo Drive&Servo Motor

    (Modicon,SMC,SICK,NORGREN,Siemens,Ebmpapst etc.)




    Quality point Isolated Form A, 16 points IC200MDL940 GE VersaMax Discrete Output Module, Relay 2 .0 A per for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Wisdomlong Technology CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)